Assembly and installation
The device can be installed only on a solid and vertical wall. Loosen the
screws of the cover (2) (see the overview of the device on page 6 to 8)
and take off the top part of the phone (1). When using the optional
accessories: headset or second headset, mount the hook (10) with two
screws (11) on the rear side of the lower part of the phone (In case of
the above accessories, the hook and the screws and also in case of all
optional accessories the cable gland is included in the respective
package). Insert four screws with a head diameter of 10 to 13 cm in the
opening (20) and mount the lower part of the phone (3) on the wall or a
panel.
The telephone network cable should be passed through the cable entry
(4) and connected to terminals 13 and 14 (A, B) in accordance with the
connection diagram.
In case of factory fitted cable glands the attached operating instructions
have to be considered.
On the telephone with a sealing plug or a 1/2" NPT metal adapter, the
customer is responsible for mounting a cable entry. Follow the
manufacturer's operating instructions supplied with the cable entry
assembly. Only cable entries with EU type approval for IP66 enclosure
protection rating and -25°C ≤ Ta ≤ 60°C should be used and they should
provide a good seal and fit tightly to the cable. If a torque of more than
20 Nm is used to tighten down the sealing rings of the cable entry, then
the side of the cable entry assembly nearest the housing should be
secured against rotating.
Prior to assembly, check cover seal for tightness.
Using the plug connector (7), plug the ribbon cable onto the pin contact
strip (8) in the upper part of the housing.
Attach the upper part of the telephone and fasten it to the lower part of
the telephone with the four cover screws (2).
The locking torque of the upper part screws is: 1.2 ... 1.5 Nm.
Regarding the assembly and installation please observe the respectively
applicable installations regulations.
15