CB-1200
6.7

Installing the water tank and hoses

To install the water tank that supplies water to the humidifier, you can
choose between one of the following options:
Install a separate 35 l water tank (accessory CB-WT35). This water tank
supplies the humidifier with 35 l of water. Once this water has been fully
consumed, the tank must be manually refilled.
You can install the 35 l water tank in either a vertical or horizontal position.
Fasten it with the enclosed perforated tape to the vehicle floor or wall (f ).
Install a 10 l buffer tank (accessory CB-WT10). The buffer tank holds
10 l of water for the humidifier. When the water level falls below a certain
point, it is automatically refilled from the fresh water tank of the caravan.
Make sure that you do not kink any hose that you lay! (6 )
The hoses must run in a downward direction from the system to the
water tank. The hose must never by laid in an upward direction nor
horizontally! Furthermore, the hoses must be laid without bends!
Since a caravan is slightly lower at the front than at the rear, the hose for
the water drain line should be laid in a forward direction from the roof unit.
If the water supply line is not properly laid, this will reduce the system's
cooling capacity.
If the water drain line is not properly laid (or if it is dirty), the water may not
be returned to the tank but discharged over the roof.
6.7.1 Installing the 35 l water tank
➤ Fasten the water supply hose (hose ∅ 6 mm) from the fresh air cooling
system to the pump outlet of the 35 l water tank (d 6, page 7).
➤ Fasten the water drain (hose ∅ 8 mm) from the fresh air cooling
system to the returnline connection of the 35 l water tank
(d 5, page 7).
➤ Connect the water level sensor cable from the fresh air cooling system
to the 35 l water tank (d 8, page 7).
➤ Connect the pump cable (d 7, page 7) to the power supply
(b 3, page 6).
➤ Connect the plug from the 230 V pump cable of the system to the 2-
wire cable of the power supply (b 3, page 6).
All manuals and user guides at all-guides.com
Installing the fresh air cooling system
(
page 6)
b ,