Installation
DO NOT connect power until installation is complete.
Installing In Window: With assistance, insert fan duct part of cooler through window.
See Fig. 2A.
Outside tank part of cooler should fit as tight to wall as possible and should be level.
Note: It may be necessary to utilize a wood spacer to keep unit straight up and down
when fastening to uneven siding. Wood stip not included. See Fig. 2A.
While holding cooler in correct position, fasten to the wall through designated screw
holes on bottom outside unit. Note: It is suggested to use support brackets on under
outdoor unit for additional support. Brackets are not included.
Lower window securely on fan duct. Fill the open window gap(s) on the sides of the
duct going through the window. Plywood or paneling is recommended. Sealant is rec-
ommended to hold panels in place and seal any gaps.
Plug unit into 115v grounded outlet. Connect water supply to the exterior part of unit.
Unit is ready to power on. See control functions on page 4.
See specifications on pg 3 for water and electrical information.
Installing Through Wall: Consult a qualified contractor to frame in opening. See dims
on page 4. Follow steps above for fastening to outside wall and using support brackets.
Refer to rough-in dims shown below. Fig. 2B.
Exterior Wall
Fig. 2A
Airflow
Interior Wall
Suggested Support
Spacer may be
needed to level unit
W6100 Manual Online 04/08/22
INDEX
Ensure unit is level
when secured in place
Safety Rules/
Getting Start-
Fig. 2B
Suggested Rough-in
ed....
Opening Through Wall
In-
22.25"
22.25"
Bracket
EN2
Operation
Operating Tips:
It is critical for optimum operation of the window cooler that there is sufficient air
openings for the area to be properly cooled. Opening doors or windows usually
accomplishes this.
For best ventilation results, it is important that doors and windows are not open
on the windward side of the house.
Rooms further away from the cooler typically require more ventilation than
rooms closest to the cooler.
Control Functions
Air Sweep Control
Specifications
High
Low
Model Speed
Volts
CFM
CFM
W6100
2
6700 4020 115
Unit Off
Fan & Pump On High Speed
Fan & Pump On Low Speed
Fan Only On Low Speed
Fan Only On High Speed
Pump Only On
Operating
High
Low
Watts Phase
Water
Amps
Amps
Pressure
3.6
2.9
320
1
60 PSI
EN3
Hessaire.com