Dimensions
Model Dim. A Dim. B Dim. C Dim. D Dim. E Dim. F Dim. H Dim. K Dim. W
W6100 21 5/8" 21 5/8"
10"
26 3/4"
Maintenance
Disconnect from power source before attempting any
maintenance or routine service. NEVER remove any access panels while unit
is in operation or plugged in. Failure to do so could lead to SERIOUS INJURY.
Cleaning And Storage:
Remove pads for cleaning. Use a soft brush. Vinegar may be used.
Drain tank and wipe dry.
Ensure pads are dry by running fan for at least 30 minutes without the pump.
W6100 Manual Online 04/08/22
10"
3 3/4" 35 1/2" 3 5/8" 29 1/4"
DEX
Safety Rules/Getting Start-
Accessing Components:
1. Remove 2 phillips screws
2. Push back panel up
3. Pull bottom of panel out
to remove.
EN4
Problem
Cooler won't turn on
Fan will not operate
IN-
Cooler does not pump
Swing does not work
ed....
Water leakage
Instal-
Water level high or low Adjust nut on float valve.
Troubleshooting
Cause / Remedy
Ensure unit is plugged in and switched on.
Receptacle breaker may need to be reset.
If unit is equipped with a GFCI plug, reset.
If unit has a timer, ensure it is off.
May need new ON/OFF switch.
Ensure fan function is on.
Make sure nothing is obstructing fan blade.
Fan motor may need to be replaced.
Fan switch may need to be replaced.
Slow running - may need capacitor replaced.
Ensure pump switch is turned on.
Make sure water level is not low. Add water.
Make sure hoses are connected and free of debris.
Pump may need to be replaced.
Pump switch may need to be replaced.
Ensure swing switch is turned on.
Make sure the linkage is connected.
Oscillation switch may need to be replaced.
Oscillation motor may need to be replaced.
Make sure drain plug is securely in place.
Make sure cooler is level.
Inspect tank for cracks.
Check media pads for water running on outside of unit.
Change pads if necessary.
Check for leaks in water distribution hose connections.
Check spreaders for build up causing spill over of
water into the airstream.
Float valve needs to be adjusted to keep water level
below overflow.
Float valve may need to be replaced.
EN5
Hessaire.com