Symbols on the machine
High-pressure jets can be dan-
gerous if improperly used. The
jet may not be directed at per-
sons, animals, live electrical equipment or
at the appliance itself.
Risk of electric shock!
Only electricians or authorised
technicians are permitted to
work on parts of the plant.
Risk of burns on account of hot
surfaces!
Risk of poisoning! Do not
breathe in the exhaust fumes.
Proper use
Cleaning of: Machines, Vehicles, Struc-
tures, Tools, Facades, Terraces, Garden-
ing tools, etc.
Danger
Risk of injury! Follow the respective safety
regulations when operating at gas stations
or other dangerous areas.
Please do not let mineral oil contaminated
waste water reach soil, water or the sew-
age system. Perform engine cleaning and
bottom cleaning therefore only on speci-
fied places with an oil trap.
Safety instructions
Please follow the national rules and
–
regulations for fuel spray jets of the re-
spective country.
Please follow the national rules and
–
regulations for accident prevention of
the respective country. Fuel spray jets
must be tested regularly and the results
of these tests must be documented in
writing.
All manuals and user guides at all-guides.com
EN
The heating appliance of the machine is
–
an ignition plant. All national laws and
regulations about heating systems must
also be followed.
As per the applicable national guide-
–
lines, the first time this high-pressure
cleaner must be taken into operation by
a skilled person. KÄRCHER has al-
ready performed this initial start-up for
you and has documented it accordingly.
The documentation can be requested at
your KÄRCHER partner. Please have
the part and plant number of the appli-
ance available when enquiring about
the documentation.
We would like to point out that the appli-
–
ance must be repeatedly checked by a
skilled person as prescribed by the ap-
plicable national regulations. Please
contact your KÄRCHER partner.
Safety Devices
Safety devices serve for the protection of
the user and must not be put out of opera-
tion or bypassed with respect to their func-
tion.
Overflow valve with two pressure
switches
While reducing the water supply at the
–
pump head or with the Servopress -
regulation the overflow valve opens and
part of the water flows back to the pump
suck side.
If the hand-spray gun is closed, so that
–
the whole water flows back to the pump
suck side, the pressure switch at the
overflow valve shuts down the pump.
If the hand spray gun is opened, the
–
pressure switch on the cylinder head
turns the pump back on.
The overflow valve is set by the manufac-
turer and sealed. Setting only by customer
service.
– 3