Descargar Imprimir esta página

Maintenance; Information For The User - Thermor AEROMAX ACCESS Serie Manual

Publicidad

Idiomas disponibles

Idiomas disponibles

Presentation
Servicing, Maintenance and Troubleshooting

1. Information for the user

The water heater must be drained when the Absence mode cannot be used or when the appliance is powered
off. Proceed as follows:
Turn off the power supply.
Open a hot water tap.

2. Maintenance

In order to maintain the performance of your water heater, it is recommended to perform regular servicing.
By the USER:
What
Safety unit
General condition
The appliance must be switched off before opening the covers.
By the PROFESSIONAL:
What
Condensate drainage
The electrical connection Once a year
Electric heating element
Scaling
Evaporator
* For dusty environments, increase the maintenance frequency.
56
Installation
When
Once or twice a month
Once per month
When
Once a year
Once a year
Every 2 years
Every 2 years*
Use
Maintenance
Close the cold water inlet.
Open the safety unit drain valve.
How
Operate the safety valve.
Check that the flow is correct.
Check the general condition of your appliance: no error
codes, no water leaks from the water connections, etc.
How
Check the cleanliness of the condensate drain pipe.
Check that no wires are loose on the wiring and that all
the connectors are in position.
Check the correct operation of the electric heating
element by measuring the power.
If the water supply to the water heater has scale,
perform descaling.
Clean the evaporator using a nylon brush and non-
abrasive and non-corrosive products.
Warranty

Publicidad

loading

Este manual también es adecuado para:

Aeromax access 200lAeromax access 250l