Descargar Imprimir esta página

Open Windows Function - Rointe SYGMA SRN0330RAD2 Manual De Instalacion Y Uso

Publicidad

Idiomas disponibles

Idiomas disponibles

STEP 3 - Select the days
The days of the week will start flashing on the display panel and will show DAY 1, DAY 2, DAY
3, etc. Use the
to select the day(s) you wish to include in your AUTOMATIC programme. The day will
stop flashing once selected. Repeat all the days you wish to program with the same settings
and once all the days are selected press the
setting.
STEP 4 - Select the hours
Once step 3 has been completed, the display will show the time in 24-hour format (midnight
is 0h, 1h, 2h...). Move through the hours using
the
key to switch between COMFORT
time you wish to change, for all the days selected in step 3. The corresponding icon for that
mode will appear at the top of the display; repeat the process of selecting the mode with
the
button each time you need it.
Once you have finished programming, press the button to end
any keys for 30 seconds. To change the programming again, go back to step 1 and proceed
as described above.If you want to activate the anti-frost mode in the hours that do not have
COMFORT or ECO mode, from the main screen of the radiator and in automatic mode, press
the key
. If you want to reverse this action, press
* If you want different schedules on multiple days within your programme, you will need to
modify each day or group of days separately, starting from the main menu again for each
day / days. Follow steps 1 to 4 above to program different days / times / temperatures.

5.7. OPEN WINDOWS FUNCTION

This function is activated when the temperature read by the probe detects a drop of 4ºC
with respect to the setpoint temperature within 30 minutes. When this function is activated,
the following image appears on the radiator display for 5 seconds:
Once the Open Windows function is activated, a screen indicating that the anti-frost mode
is active will appear with this icon
this period, if you press the
radiator will be switched on again without the Open windows function active. At the end of
a period of two hours without pressing any buttons, the radiator will automatically return to
the previous state.
16
and
buttons to scroll forward or backward through the days. Press
at the top. The mode will be active for 2 hours. During
key, the radiator will be switched off. Pressing again
button (while on day 7) to scroll to the time