Instructions
Load Sensor for Gas Springs
Technical data
Battery operated load sensor
Battery:
Auto zeroing:
Battery life:
Battery charge display:
Performance:
Accuracy:
Environmental conditions
Humidity:
Temperature:
Error messages
OVEr:
The load sensor is overloaded. Reduce the load on the load sensor.
ZerO:
Display error.
The load sensor cannot display the negative number.
Solution: reset by pressing the zero key.
Note:
Each time you press the zero key the display will briefly read "Zer0".
bAtt:
The battery is too low. Replace the battery.
If there is no response to this display, the unit will switch itself off.
FIBRO 10
9 V (disposable alkali cell or NiCad)
Errors on zero load are corrected automatically on zeroing.
> 125 h continuous operation (alkali cell)
When the battery is discharged, the display flashes "bAtt".
The equipment switches off automatically if the battery charge is too
low for reliable operation.
± 0.5% of the actual load or
± accuracy of the display (whichever is the higher value).
10 to 95%, non condensing
Operation:
-10°C to +40°C
Storage:
-40°C to +75°C
subject to alterations