1.2. Manufacturer name and address
Manufacturer name: Calpeda S.p.A.
Address: Via Roggia di Mezzo, 39
36050 Montorso Vicentino - Vicenza / Italia
www.calpeda.it
1.3. Authorised operators
The product is intended for use by expert operators
divided into end users and specialised technicians
(see the symbols above).
It is forbidden, for the end user, to carry
out operations which must be done only by
specialised technicians. The manufacturer
declines any liability for damage related to the
non-compliance of this warning.
1.4. Warranty
For the product warranty refer to the general terms and
conditions of sale.
The warranty covers only the replacement and
the repair of the defective parts of the goods
(recognised by the manufacturer).
The Warranty will not be considered in the following
cases:
1. Whenever the use of the device does not conform
to the instructions and information described in this
manual.
2. In case of changes or variations made without
authorization of the manufacturer.
3. In case of technical interventions executed by a
nonauthorised by the manufacturer personnel.
4. In case of failing to carry out adequate
maintenance.
1.5. Technical assistance
Any further information about the documentation,
technical assistance and spare parts, shall be
requested from manufacturer.
2. TECHNICAL DESCRIPTION
Pumps control device provided with flow rate and
pressure sensor The electronic controller IDROMAT
controls the automatic start and stop of the water
pump when opening or closing any tap or valve of
the installation. When the water pump starts, it keeps
running while there is any tap opened in the system,
giving the required flow at constant pressure to the
network.
Pump type
Restart
pressure
IDROMAT 5-15
1,2 bar
IDROMAT 5-18
1,5 bar
IDROMAT 5-25
2,2 bar
IDROMAT 5-33
3,0 bar
IDROMAT 6-15
1,5 bar
IDROMAT 6-30
3,0 bar
IDROMAT 5e
1,5 bar
IDROMAT 5e
2,0 bar
IDROMAT 5e
2,5 bar
ISTR_IDROMAT_Rev02 - Operating Instructions
Highest
Pump
plant point
head
< 12 m
> 25 m
< 15 m
> 30 m
< 22 m
> 35 m
< 30 m
> 45 m
< 15 m
> 30 m
< 30 m
> 45 m
< 15 m
> 30 m
< 20 m
> 35 m
< 25 m
> 40 m
2.1. Intended use
For clean liquids, non-explosive or flammable, without
abrasives.
The electric control system can be used for
both potable and non-potable water. In case
of installations in which is possible to use the
two kinds of water, make sure that the potable
water circuit comes into contact with non-
potable water. (follow the laws in effect in the
Country in which the product is installed).
2.2. Uncorrect usage reasonally to forecast
The device is designed and built only for the purpose
described in (Paragraph 2.1).
Improper use of the device is forbidden, as
is use under conditions other than those
indicated in these instructions.
Improper use of the product reduces the safety and
the efficiency of the device, Calpeda S.p.A. shall not
be responsible for failure or accident due to improper
use.
Do not use in ponds, tanks or swimming
pools or where people may enter or come into
contact with the water.
3. TECHNICAL FEATURES
3.1. Technical data
The device runs correctly only if all the following
features are respected.
Protection IP 65
Supply voltage/ Frequency:
115V 1~ ±10% (IDROMAT 5e not included)
230V 1~ ±10% 50/60Hz
Max. current value:
8 A IDROMAT 5
16 A IDROMAT 6
Working temperature: 0 ÷ + 65 °C
Max. working pressure: 12 bar
Relative
Humidity:
from
condensation
Maximum working rate: 10 m³/h (12 m³/h IDROMAT 6)
20
to
90%
without
Page 9 / 52
EN