OVERVIEW OF SETTINGS
Back
More
PRESETTINGS
IR: IMMUNITY
IR: FREQUENCY
More
Back
Back
More
IR: WIDTH
+
service
IR: NUMBER
mode
IR: PRESENCE TIME
motion
IR: OUTPUT
REDIRECTION
safety
FACTORY RESET
More
Back
ZIP CODE
all parameter settings in zipped format
(see application note on ZIP CODE)
ID #
unique ID-number
ERROR LOG
last 10 errors + day indication
IR: SPOTVIEW
view of spot(s) that trigger detection
IR: C1 ENERG
signal amplitude received on curtain 1
IR: C2 ENERG
signal amplitude received on curtain 2
0
1
2
3
shopping
critical
standard
street
env.
< 2.8 m
normal
high
low
Sensors mounted close to each other should
A
B
have a different frequency.
factory value
service mode = no IR detection during 15 minutes (maintenance).
1
2
This value excludes conformity of the door system to EN 16005 and DIN 18650.
15 s
30 s
1
min
NC
NO
NC
NO
NC
NC
safety
0 presence detection on safety input
+
1 presence detection on safety and opening input
opening
4
5
6
7
factory values for IR immunity and IR number
increased immunity
increased immunity, 1 curtain
> 2.8 m
higher highest
normal
high
excludes conformity of the door system
according to EN 16005 / DIN 18650 / BS 7036
2
5
10
20 min 60 min infinite
min
min
min
NO
NO
POWERSUPPLY
OPERATINGTIME
RESET LOG
PASSWORD
LANGUAGE
ADMIN
8
9
For conformity to EN 16005 or DIN 18650 at a
mounting height of 2.8 or more, use values 6 and 7.
For conformity to BS 7036 at a mounting height
of 2.2 m or more, use values 6 and 7.
Always additionally adjust
the arrow position on the
sensor with a screwdriver.
min. value for DIN18650: 1 min
min. value for EN16005: 30 s
NO: normally open
NC: normally closed
full
partial: outputs are
partial
not reset
reset
reset
supply voltage at power connector
power duration since first startup
delete all saved errors
LCD password
(0000= no password)
language of LCD-menu
enter code to access admin mode
5