Descargar Imprimir esta página

Technical Specifications - BEA SLIDER radar Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TECHNICAL SPECIFICATIONS

Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Detection mode:
Technology:
Output:
Test input:
Norm conformity:
Only for EC countries: According to
the European Guideline 2012/19/EU
for Waste Electrical and Electronic
Equipment (WEEE)
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%
< 2.5 W
2 m to 3.5 m
(local regulations may have an impact on the acceptable mounting height)
-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
EN 12978; EN 61000-6-2; EN 61000-6-3; EN ISO 13849-1 PL «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle);
EN 62061; EN 61496-1 ESPE Type 2; EN 50581
EN 16005 Chapter 4.6.8; DIN 18650-1 Chapter 5.7.4; BS 7036-1 Chapter 8.1; EN 60825-1
(to be operated from SELV compatible power supplies only)
Specifications are subject to changes without prior notice.
AUTOMATISMI PER CANCELLI
AUTOMATIC ENTRY SYSTEMS
All values measured in specific conditions.