4 Set the temperature by pressing "" or "".
Temperature range can be set between 10°C and 16°C.
Keep pressing and the value will change more quickly.
5.5.3 To cancel leave home operation
• Press "
" (START/STOP). Or
• Select "Leave Home" from the menu and press "OK".
The confirmation screen will be displayed.
Select "Yes" by pressing "" or "" and press "OK". Or
• Change to other operation mode.
Press "" and select "MODE". By pressing "" or "",
the leave home operation will be canceled and the
operation mode is changed.
ex. Select heating mode
NOTE
• During leave home operation, fan speed and air deflector's
position cannot be changed.
• When leave home operation is started, implementation of
"Simple timer" or "Weekly timer" is canceled.
• After reaching the set number of operation days for leave
home or leave home operation is canceled, the unit will
operate in previous mode.
• Powerful and Eco operations are not applicable during
leave home operation.
• For multi connection:
– Fan/Cooling/Dehumidifying and leave home cannot
operate at the same time. The first-run unit has a priority
and other units in different mode will be in standby mode.
– Heating operation can be used with leave home.
– When two or more rooms are set to operate leave home,
the temperature set by leave home may not be reached. It
also depends on outdoor temperature.
NOTE for Timer Operation
• The timer lamp indication of indoor unit when the timer
operation set in this remote controller.
The kind of Timer operation
Simple timer
Sleep timer
Weekly timer
Day timer of leave home
• If this remote controller is connected to the indoor unit,
you cannot set the timer operation at the wireless remote
controller.
- 16 -
Timer lamp indication of
indoor unit
OFF
ON
OFF
OFF