Descargar Imprimir esta página

Stopping The Engine; Maintenance; Periodic Maintenance Chart - Maruyama MD181DX CE Manual Del Usuario

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42

STOPPING THE ENGINE

Close the Mist cock, and stop spraying.
Always run the engine at idle speed for a few minutes to allow cooling before stopping. To stop the
engine, move the throttle control lever all the way to the engine stop position.
CLEANING THE PRODUCTS
Remove Mist hose from Mist pipe, and discharge chemical from chemical tank.
After recovering the remnant chemical, clean the inside chemical tank using clean water.
Also wash the spray nozzle with clear water.

PERIODIC MAINTENANCE CHART

WARNING
• Do not attempt to start or operate a mist blower that indicates a fuel leak.
• Always remove the spark plug cap from spark plug when servicing the engine to prevent
accidental starting.

MAINTENANCE

Check and replenish fuel
Check for fuel leakage
Check bolts, nuts and screws
for looseness and loss
Clean fuel filter
Clean air filter element
Tighten bolts and nuts
Clean spark plug and adjust electrode gap
M ★ Remove dust and dirt from cylinder fins
M
Remove carbon deposits on piston head
and inside cylinder
M
Remove carbon deposits in the exhaust pipe
of muffler
M
Clean net of spark arrester (if equipped)
M
Check the sliding portion of crankshaft,
connecting rod etc.
Fuel tube
Note: The service intervals indicated are to be used as a guide. Service to be performed more
frequently as necessary by operating condition.
M: Service to be performed by an authorized Maruyama engine dealer.
★ : Service more frequently under dusty conditions.
WASHING
DISCHARGING
MISTCOCK OPEN
MAINTENANCE
Daily
9
Interval
First
Every
20 hours
20 hours
It is recommended to replace every 3 years.
DISCHARGING
Every
Every
50 hours
100 hours

Publicidad