Installation
Connect vent system
1.
Measure from the wall or roof outlet to the to the top
ceiling. Cut the ductwork at the measured dimension
and place it over the transition.
2. Seal connection with clamps.
3.
Use caulk to seal all openings.
Electrical connection
WARNING
ELECTRICAL SHOCK HAZARD.
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1.
Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and
install a UL listed or CSA approved ¹⁄₂" strain relief.
B
A
A. Terminal box cover
B. Strain relief
Roof Outlet
Wall
Outlet
4. Run home power supply cable through strain relief,
into terminal box.
A
B
E
D
F
C
5. Use UL listed wire connectors and connect black
wires (C) together.
6. Use UL listed wire connectors and connect white
wires (E) together.
WARNING
ELECTRICALLY GROUND FAN.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO
CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
7.
Connect green (or bare) ground wire from home
power supply to yellow-green ground wire (F) in
terminal box using UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
Dimension to
Measure
A. Home power supply
cable
B. UL listed or CSA
approved strain relief
C. Black wires
D. UL listed wire
connectors
E. White wires
F. Green (or bare) and
yellow-green ground
wires
ENGLISH