All manuals and user guides at all-guides.com
Operation
1. The meter automatically selects the proper measurement according to the
following table.
Priority
1
2
3
4
2. Refer to "Typical Measurements" for specific measurement instructions.
3. Test the unit on a known functioning circuit or component of the type you intend
to measure.
• If the unit does not function as expected on a known functioning circuit,
replace the battery.
• If the unit still does not function as expected, send the unit to Greenlee for
repair. Refer to the instructions under the Warranty.
4. Take the reading from the circuit or component to be tested.
8
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
Display
AC volts or DC volts,
whichever is greater
Resistance and
continuity
Diode test
AC amps
Conditions
Input at terminals is
1.3 to 600.0 VAC
2.1 to 600.0 VDC
-0.7 to -600.0 VDC
Input at terminals is
0 to ∞ Ω
0 to 0.9 VAC
1.0 to 2.0 VDC
-0.2 to -0.4 VDC
Input at terminals is
0.4 to 0.8 VDC
AC current through jaw is
0.9 to 400.0 A