8. INFLATION: PCS
WARNING
CHECK THAT THE PRESSURE CONTROL HOSE IS ALWAYS CONNECTED TO
THE INFLATOR AND TO THE INFLATABLE ITEM
1. Connect the inflation hose to the PCS outlet port (point 2,
figure on page 3) and to the main valve of the inflatable item
2. Connect the pressure control cable with the adapter to the
item auxiliary valve
WARNING
MAKE SURE THAT THE AUXILIARY VALVE FOR PRESSURE CHECK IS SUITABLE FOR THE PCS SENSOR CONNECTOR
3. Connect the sensor cable to the PCS connector (point 3, figure on page 3)
4. Connect the power plug (point 5, figure on page 3) to a suitable socket
5. Switch on the green switch on the inflator (point 1, figure on page 3). The light on the switch will light up
6. 2 LEDs light up and after 4 seconds the red LED turns off; the green LED indicates that the PCS will
automatically start to inflate to the set pressure.
9. INFLATION: PCS-IC (INTERNAL CONTROL)
1. Connect the inflation hose to the PCS outlet port (point 2, figure on page 3) and to the main valve
of the inflatable item
2. Connect the power plug to a suitable socket (point 5, figure on page 3)
3. Switch on the green switch on the inflator (point 1, figure on page 3). The light on the switch will light up
4. 2 LEDs light up and after 4 seconds the red LED turns off; the green LED indicates that the PCS will
automatically start to inflate to the set pressure.
WARNING
THE INFLATION/CHECK PRESSURE CAN ONLY BE CHANGED AT A SCOPREGA SERVICE CENTRE
10. DEFLATION - PCS AND PCS-IC
1. Connect the hose to the PCS deflation port (point 4, figure on page 3) and to the main valve of the
inflatable item
2. Connect the power plug to a suitable socket (point 5, figure on page 3).
3. Switch on the green switch on the inflator. The light on the switch will light up (point 1, figure on page 3).
4. 2 LEDs light up and after 4 seconds the red LED turns off; the green LED indicates that the PCS will
automatically start to deflate.
WARNING
DEFLATION DOES NOT STOP AUTOMATICALLY. SWITCH OFF THE INFLATOR ONCE THE INFLATABLE UNIT IS COMPLETELY
EMPTIED.
12
11. TROUBLESHOOTING
Pressure Sensor Cable
INFLATING
TUBE
230V/120V
50Hz/60Hz
fig.2
11.1 ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.
PROBLEM
POSSIBLE CAUSE
The power cable is not connected to
the socket
The PCS does
not start
The main GREEN switch is off
The power cable is damaged
Pressure sensor not properly
connected
The power cable is not
connected to the socket
The main switch is off
The inflator is
stopped
Over-temperature
The power cable is not connected to
the socket
GREEN LED off
The power cable is damaged
POSSIBLE SOLUTION
Connect it correctly
Press the switch
Ask the SCOPREGA service to replace
or repair the cable
Connect the pressure sensor
Connect it correctly
Press the switch
Wait until the PCS motors cool down.
The inflator will restart automatically.
Connect it correctly
Ask the SCOPREGA service to replace
or repair the cable
13