Installation Instructions
Installation Instructions
We recommend that a qualified technician install the range hood. It is
the installer's responsibility to ensure the range hood complies with the
installation clearances specified for the product.
• It is recommended that the vent system be installed before the hood is
installed.
• If possible, disconnect and move freestanding or slide-in ranges from
cabinet openings to provide easier access to the rear wall.
• Before making cutouts, make sure there is proper clearance within the
ceiling or wall for the exhaust vent.
• Confirm that all installation parts have been removed from the shipping
carton.
1. Turn off the power at the circuit breaker panel or fuse box.
2. Determine which venting method to use: roof, wall, or non-vented
(recirculating).
3. Select a flat surface for assembling the range hood.
Place a covering over that surface.
Venting Methods
Outside Top exhaust
Use 7" (17.8 cm) or larger round vent with a maximum length of 50 ft
(15.2 m) for vent system.
Use the diagram or the hood as a template and mark the locations for the
ductwork, electrical wiring and keyhole screw slots.
C
1
1
"
D
⁄
(3.95 cm)
2
7" (17.8 cm)
E
A
B
C
D
E
CL
10" 25.4 cm
" (8.3 cm)
3
1
⁄
4
A
30" (76 cm)
18
⁄
" (47.5 cm)
3
4
1" (2.5 cm)
1½"
(3.8 cm)
9" (22.8 cm)
WARNING
USE TWO OR MORE PEOPLE TO MOVE AND INSTALL THE RANGE
HOOD. FAILURE TO DO SO CAN RESULT IN INJURY.
NOTE
Mark the Range Hood knockouts on the wall and make the necessary
cutouts before installing the hood.
Prepare the location
A
1. If cabinet has recessed bottom, add wood filler strips on each side.
Install 4 flat head wood screws with washers and nuts to attach filler
strips in locations shown.
NOTE
For installations to a surface other than drywall, it is recommended that a
qualified contractor determine the anchoring method.
NOTE
Consider use the A measure for 7"(17.8 cm) round transition and B
measure for recirculating system.
A. 14½" (36.7 cm)
B
B. 12 1/4" (31.1 cm)
2. Remove the grease filter by pulling the filter latch toward the back of
the range hood and using a Torx T10 adapter, remove the screw from
the filter retainer.
3. Remove the lateral panels by pulling them horizontally to the back of the
hood and then release the brackets on the front.
Wood filler strips
(recessed cabinet
bottoms only)
Cabinet
bottom
B
A
A
Wall
English
7