The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessibile.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, ECI norms.
The appliance is supplied without the connection cable. To install the power supply cable, proceed as follows:
•
Disconnect the power supply.
•
Remove the front panel
•
Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
•
Block the cable with the cable blocker, and reassemble the front panel. The earth wire must be longer than the
others so that if the cable blocker should break, it will disconnect after the tension wires.
The connection cable must have an adequate section for the power of the appliance and be resistant to a temperature of
at least 150°C (see technical data table).
GB
TECHNICAL DATA TABLE
CP-74ET
40x70x90
400VAC/3N 50/60 Hz 400VAC/3N 50/60 Hz 400VAC/3N 50/60 Hz
8,75 A
6 kW
5x1 mm²
TRANSFORMATION
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
IE
CP-76ET
60x70x90
13,71
9,5 kW
5x1,5 mm²
18
CP-78ET
80x70x90
17,5 A
12 kW
5x2,5 mm²