Place the saw frame on the stand and tighten
the stand knobs for safety (see FIGURE 4).
You may need to move or remove water tray
to easily secure safety knobs to stand frame.
FIGURE 4
B. Motor ASSeMBLY
InStALLAtIon
STEP 1: Install the motor frame assembly into
the motor support arm (see FIGURE 5).
STEP 2: Pre-fix the red motor frame locking
knob into the hole provided, as shown. This
knob is also used to fine-tune the alignment
of the motor frame assembly.
STEP 3: Remove the rubber cap to expose
hex nuts. Firmly drive the three hex bolts
into the motor support arm with Allen key
provided and secure the motor frame
locking knob.
Motor
frame
Rubber
locking
cap
Motor
knob
support
arm
FIGURE 5
STEP 4: Place rubber cap back over
hex nuts.
C. InStALLIng
upper FrAMe WHeeLS
Secure the 4 in. wheels at the two ends of
the base frame with hex bolts and nuts, as
shown (see FIGURE 6).
FIGURE 6
All manuals and user guides at all-guides.com
d. InStALLIng tHe
Cord CoLLeCtIng
HAnger / tooL CAddY
Secure the hanger onto the motor support
arm with 2 bolts (see FIGURE 7). Place 2
wrenches in hanger and place Allen key in
opening provided.
FIGURE 7
e. dIAMond BLAde
InStALLAtIon
STEP 1: When installing the blade, separate
the two water feed hoses inside the blade
guard to allow the blade to sit between them
(see FIGURES 8a and 8b).
FIGURE 8a
FIGURE 8b
STEP 2: Lift the blade guard and lock in place
with the knob holding the blade guard.
STEP 3: Hold the blade lock nut with
the provided 23 mm wrench and also
hold the blade shaft with the other
provided 10 mm wrench. At the same time,
move the wrenches upward to loosen or
downward to tighten (see FIGURE 9) in order
to open and close the blade shaft nut and
outer flange. Then, attach and secure the
blade onto the blade shaft, keeping the inner
flange in place. Place the blade between
the two water tubes in the back of the blade
guard.
FIGURE 9
MAkE SURE THAT
THE DIRECTIONAL ARROW ON THE BLADE
POINTS IN THE SAME DIRECTION AS
THE ARROW MARkED ON THE BLADE
GUARD FIxING PLATE.
– 4 –
STEP 4: Replace the blade guard to its
original position and tighten knob.
STEP 5: To remove or change the blade, just
reverse the installation steps.
F. WAter puMp
InStALLAtIon
STEP 1: Make sure the water pump (see
FIGURE 10) is not cracked or damage in
any way.
STEP 2: Attach the end of the tube to the
pump nipple and L-shaped water flow at the
back of blade guard.
STEP 3: Place the pump at the location in the
water tray that has been designed to secure
the pump during use.
STEP 4: Pour the water into the water tray
and make sure the water level is higher than
the pump intake nozzle.
STEP 5: Keep the power cord end out of
water and plug the power cord into the
3-prong receptacle on the side of the cutting
head assembly. The pump is activated by the
ON/OFF switch of the tile saw.
STEP 6: Make sure that the water valve
connecting the pump to the tubing is in the
full open position.
FIGURE 10
NOTE: THE FOLLOWING ARE WATER PUMP
SAFETY GUIDELINES
• Make sure the pump is connected to
grounding-type receptacle to prevent the
electric shock.
• Make sure the pump and tube is settled
steadily to reduce any chance of
pump damage.
• Do not handle the pump by the power cord,
with wet hand, or when standing on a
wet surface.
• Never use the pump for anything other than
water, especially gasoline, kerosene, or
other combustible or corrosive liquids.
• Do not attempt to check the pump before
disconnecting the power source if the
pump fails to operate.
• Never operate the pump without water. The
pump needs water to cool its own motor. A
dry pump may cause damage or danger.
g. reAr WAter
CoLLeCtIon
trAY InStALLAtIon
Insert and attach the rear water collection
tray to the main water tray at the corre-
sponding joints (see FIGURE 11).