Descargar Imprimir esta página

Set Of The Room Temperature - Ravelli R 1000 Pro Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para R 1000 Pro:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 225
EN
Rev.1 29/07/2021
Pag.38
��
The appearance of the "SET RDS" message indicates that the initial parameter testing and calibration procedure was not
carried out correctly. This indication does not imply blocking the stove (see SIGNALING POP UP section).
Failed ignition
If the system does not detect the ignition of the flame within the preset time, operation will be blocked with the "No ignition" alarm.
Before relighting the stove, check that there are pellets in the hopper, that the door and ash drawer compartment are closed, that
there are no obstructions to the combustion air inlet system and above all that, in models without self-cleaning fire pot, the fire pot is
empty, clean and correctly positioned. If the problem persists, it could be due to a technical problem (ignition plug, adjustments, etc
...), so please contact a Ravelli CAT.
The accumulation of unburned pellets in the fire pot after a failed ignition must be removed before proceeding with a new
ignition.
The fire pot could be very hot: danger of burns
Never empty the fire pot inside the hopper.

Set of the room temperature

The functioning of the stove with room thermostat activated is of 3 types:
-With supplied room sensor positioned on the backside of the stove
-With room sensor integrated to the display (recommended for use with wall mounted display only)
-With external thermostat
Press key 1 from the "Home" screen to enter the room temperature setting page
Set the desired temperature with keys 1 and 2. The selectable values are: EST, from 7 °C to 40 °C (or from 44 °F to 104 °F), MAN.
The EST value must be selected if you want to use the external thermostat and MAN when you want to make the stove work at con-
stant power.
To go back directly to the "Home" screen, press keys 1 and 2 at the same time, or press OK to go to "Console probe".
By enabling the "Console probe" function, the temperature reading with the ambient probe integrated in the display is enabled. Enable
the function with key 2 and disable it with key 1. To return to the Home screen, press OK
If you use an external thermostat correctly connected as shown in the electrical scheme, the display will not show the room temper-
ature but the writing T ON ( when the contact is closed) or T OFF ( when the contact is open).
To use the external thermostat, the "console probe" must be deactivated.
The room temperature will be adjusted by the external thermostat.
Once reached the set temperature of the thermostat the display will show MODULATION, so the stove will reduce to minimum the
pellet consumption and the power as well. If activated the mode COMFORT CLIMA, the stove will switch on and off automatically.
N.PEL.
��
If you want to use the COMFORT CLIMA is advisable an external thermostat with OFF-SET of at least 3°C.
Use and maintenance manual R 1000 Pro
N.H2O
N.AMB.
TERM.
-TC1+
Rosso
Blu
Nero
Nero
N.AMB.
1
2
3
4
5
6
SONDA
TERMOSTATO
AMBIENTE
TERM.
-TC1+
7
8
9
10
SONDA FUMI
ESTERNO

Publicidad

loading