Quick start guide
English
Reference
KP 110-RF / KP 111-RF
KT 110-RF
KT 150-RF
KTU 210-RF
KTR 310-RF
KTT 310-RF
Operating temperature, protection of the instruments and information about storage and the battery
•
Operating temperature: 5 to 50 °C (KP 110-RF, KP 111-RF); -40 to 70 °C (KT 110-RF, KT 150-RF,
KTU 210-RF, KTT 310-RF, KTR 310-RF).
•
KP 110-RF, KP 111-RF, KT 110-RF, KT 150-RF, KTU 210-RF, KTR 310-RF: IP65. KTT 310-RF: IP54.
•
Storage temperature: from -40 to +85 °C
Battery power supply: lithium AA 3.6 V
1
Display
KP 110-RF / KT 150-RF:
KT 110-RF / KTU 210-RF
KTT 310-RF / KTR 310-RF:
2
Dimensions (mm)
KP 110-RF
74.4
39.8
Parameters
Pressure
Temperature / Current / Voltage / Pulses
Temperature
Current / Voltage / Pulses / Light
Pt100 temperature
Thermocouple temperature
END
DATASET is finished
REC
One value is being recorded
LOG
Flashing: dataset has not started yet
Constant: data set is in progress
FULL
Slow flashing: dataset is taking 80-90% of storage capacity
Fast flashing: dataset is taking 90-100% of storage capacity
Constant: storage capacity filled up
Channel No. which is measuring
1
ACT
Refresh of displayed measurements
TIME
Display of measurement and recording intervals
Low battery indicator
MIN
Displayed values correspond to maximum and minimum values of
MAX
the channels
Alarm action type: rising or falling action
Indicates the reception powerful of the datalogger
KT 110-RF
KT 150-RF
74.4
74.4
39.8
KTR 310-RF / KTT 310-RF
74.4
3
Connections
KP 110-RF
Ribbed connectors
KTU 210-RF
Mini-Din connectors
5
Recorder function
KISTOCK datalogger is supplied turned off to save battery life. To activate it:
• Press "OK" key for 5 s, green LED "On" blinks.
To turn it off:
• Press "Select" and "OK" keys at the same time for 5 s.
It is impossible to turn it off during a recording or a data download.
Activate or deactivate the keys during a measurement dataset:
• Press "Select" and "OK" at the same time for 5 s to deactivate both buttons: red LED
flashes twice quickly.
• Press "Select" and "OK" at the same time for 5 s to reactivate them: green LED
39.8
flashes twice quickly.
Perform an autozero during a measurement dataset (KP 110-RF)
It is possible to make the instrument to perform an autozero during a measurement dataset.
Keys must be activated.
• Disconnect the pressure tube from the instrument.
• Press "OK" key during 5 seconds.
The instrumetn performs the autozero: "0" is displayed on the screen, this value is not recorded.
• Connect again the pressure tubes.
The instrument starts again the measurements dataset and values are recorded.
KTU 210-RF
74.4
74.4
39.8
39.8
KT 110-RF
Mini-Din connector
KTR 310-RF
Mini-Din connections for Pt100 probes
Connectors for thermocouple probes
KTT 310-RF