Specifications
Installation Requirements
The oven can be installed in a standard or flush inset
application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
Minimum Base Support
TRIM OVERLAP
Top
Bottom
Sides
Electrical Requirements
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
For ease of installation, the electrical supply for the oven
should be placed in an adjacent cabinet within reach of the
conduit.
Performance may be compromised if the electrical supply
is less than 230 volts.
The oven is supplied with a cable consisting of two hot
lead conductors and a ground conductor. The wiring dia-
gram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS
68 kg
Electrical Supply
grounded, 230 VAC, 50 Hz
3 mm
Service
16 amp dedicated circuit
0 mm
Cable Length
22 mm
Total Amps
Max Connected Load
RATING PLATE
Rating plate location
IMPORTANT NOTE: Connection of this appliance should
be through a fused connection unit or a suitable isolator,
which complies with national and local safety regulations.
The on/off switch should be easily accessible after the
appli ance has been installed. If the switch is not acces-
sible after installation (depending on country) an additional
means of disconnection must be provided for all poles of
the power supply. When switched off there must be an all
pole contact gap of 3 mm in the isolator switch. This 3 mm
contact dis connect gap must apply to any isolator switch,
fuses and/or relays according to EN60335.
1.2 m
16
3.3 kW
wolfappliance.com | 3