Descargar Imprimir esta página

Troubleshooting Guide - Venga VG ACM 3000 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TROUBLESHOOTING GUIDE

Symptom
Water level indicator lights up
The unit is not
operating
Check the room temperature.
Check the air filter for dust.
Check if the air duct is blocked.
The unit works
Room door or window open.
with reduced
capacity.
Mode or temperature wrongly
set.
The exhaust pipe is detached.
Overflow while moving the unit.
Water
Leakage
Check if the drain pipe is kinked.
Incorrect positionning.
Check if any loose, vibrating
Excessive
parts.
Noise
Noise sounds like water flowing.
Communication faults between
E0
main PCB and display PCB.
Ambient temperature sensor
E1
Error
failure
Codes
E2
Coil temperature sensor failures.
Ft
Condensate water level alarm.
Problem
Solution
Empty the water tank.
The device operate from 5 to 35°C
Clean the air filter.
Clear from obstacle.
Keep the door and windows
closed.
Set the mode and temperature
according to the manual.
Securely attache the exhaust pipe.
Empty the tank before moving the
unit.
Straighten the drain pipe.
Install according to the manual
Secure and tight the vibrating parts.
Normal sound of the flowing
refrigerant content.
Check the wire harness of the
display PCB for damage.
Check connection or replace it.
Check connection or replace it.
Empty the water tank.
13
ACM 3000

Publicidad

loading