Operating instructions SATA air regulator
EN
Notice!
After being attached to the carrying strap, the air regulator can be
placed at an angle from the base position if required. Individual locking
positions are 22.5° and 45° forward or backward.

5. Scope of Delivery

■ SATA air regulator
■ CCS-disks, 1 bag (red, black, green, blue), red is mounted

6. Technical Design

CCS-disk
[2-1]
Air volume flow controller 
[2-2]
Connection spray gun
[2-3]
[2-4]
Cover bracket, can be
folded out
Connection compressed air
[2-5]

7. Technical Data

Description
Required operating pressure with-
out spray gun
Necessary operating pressure with
spray gun (in combination with 1.2
m spray air hose Art. No. 13870)
Maximum allowable operating
pressure for the PPE
Required minimum volume flow
Maximum flow rate (6 bar, air regu-
lator open wide)
Operating temperature
Storage temperature
Max. tube length
Noise level (2.5 bar, air regulator
completely closed)
Noise level (6 bar, air regulator
completely open)
52
supply
Connection breathing pro-
[2-6]
tection hood
[2-7]
Fastening module, rotating
[2-8]
Adapter plate
2,5 bar – 3,0
bar
4,0 bar – 6,0
bar
10,0 bar
150 Nl/min
740 Nl/min
5 °C – 60 °C
-20 °C – 60 °C
40 m
Unit
35 psi – 44 psi
58 psi – 87 psi
145 psi
5,3 cfm
26,1 cfm
41 °F – 140 °F
-4 °F – 140 °F
64 dB (A)
79 dB (A)

Publicidad