DE
EN
5. Starting
Before first use, the battery must be charged for approx. 10-12 hours to ensure a full charge.
Fig. 1
Fig. 3
The switch (fig. 4) can be set in 3 positions:
ON:
OFF:
OUT:
Fig. 4
Note:
The pump has a suction height of approx. 3m with a filled hose. With an empty hose,
the suction height is approx. 1m.
Abb. 5
Fig. 5
The mobile pump has a pressure sensor. The motor speed adjusts to the flow rate. When the pressure
valve is closed, the motor switches off automatically.
Fig. 5:
green flashing
Fig. 6:
blue / orange light Valve is open, maximum flow rate
Fig. 7:
blue / green light
Fig. 8:
orange light
blue / red glowing
FR
ES
Fig. 2
Pump is running
pump is switched off, key is locked in place
position to remove the key,
pump is locked
Fig. 6
Pump is ready for operation, no water delivery.
Sensor is active, motor speed adapts to flow rate
Pump draws air
Error / carry out restart
IT
Fig. 1: The tank is connected to the
mobile pump via the suction
connection (inlet).
Fig. 2: The pressure connection
(outlet) connects the mobile pump
with the spray gun / hand shower.
Fig.3: The battery must also be
connected to the pump. To do this,
remove the battery from the
aluminium case and insert the pump
plug into the socket.
Fig. 7
11
Fig. 8