BTL PA0400- _ _ _ _ -C12NL _ _ 0-000S04
Magnetostrictive Linear Position Sensor – Profile Style
9
Technical data
The values are typical for the
BTL PA0400- _ _ _ _ -C12NL _ _ 0-000S04 at 24 V DC,
room temperature and a measurement length of 500 mm
together with magnet BTL6-A-3800-2 or BTL6-A-3801-2.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Typ. temperature coefficient
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock per
EN 60068-2-27
2), 3)
Vibration per EN 60068-2-6
Protection per IEC 60529 (when
threaded together)
9.2
Detection range/Measuring range
Measuring length
Resolution
Repeat accuracy
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
Non-linearity
Detectable speed
14
english
−25...+85 °C
−40...+100 °C
≤ 90%, non-
condensing
≤ 30 ppm/K
1)
100 g/6 ms
50 g/2 ms
12 g,
2), 3)
10...2000 Hz
IP67
25...4000 mm
5 μm
≤ ±10 µm
1000 Hz
500 Hz
250 Hz
± 50 µm
≤ 10 m/s
9.3
Electrical data
Operating voltage U
b
Current draw (at 24 V DC)
Power consumption
Overvoltage protection
Voltage-proof up to (GND – Housing)
9.4
Electrical connection
Short circuit protection
Polarity reversal protected
9.5
Interface
IO-Link version
Transmission rate
Cycle Time
Data format
Error value
Measuring length 500 mm, magnet in the middle of the measuring range
1)
2)
Individual specifications as per Balluff standard
Resonant frequencies excluded
3)
18...30 V DC
≤ 60 mA
≤ 1.5 W
U
up to 36 V DC
b
500 V DC
Signal output to
GND and 30 V DC
U
up to 30 V DC
b
1.1
COM2 (38.4 kBaud),
COM3 (230.4 kBaud)
≥ 1 ms
32 Bit signed
0x7FFFFFFC