Specifications
E
Light Source
Laser Wavelength
Laser Power
Working Range
Accuracy (Level):
Battery Low
Unit Not Powered Off With
Pendulum Lock Switch
Flashing Laser Beams
Power Source
Operating Temperature
Storage Temperature
Humidity
Environmental
20
Laser diodes
510-530 nm (GREEN)
≤1.5mW (each beam) CLASS 2 LASER PRODUCT
100' (30 m)
165' (50 m) with Detector
± 1/8" per 30' (±3.1mm per 9 m)
1 x LED Flashing on Battery meter
4 x LED Flashing on Battery meter
Tilt range exceeded/unit is not level
D
WALT 12V MAX or 20V MAX Battery Pack
e
14 °F to 122 °F (-10 °C to 50 °C)
-5 °F to 140 °F (-20 °C to 60 °C)
Maximum relative humidity 80% for temperatures up to 88 °F
(31 °C) decreasing linearly to 50% relative humidity at 104 °F
(40 °C)
Water & Dust Resistant to IP54