Alternatively, the interface can be connected to a CDC4 BUS 1
via the 4-pin plug-in RS-485 socket (Figure 1, item 14).
See also Figure 2.
Figure 2: Example of CDC4 door controller connection
(A) 2-way lock power cable
(B) 4-way data bus cable
(C) 2-way lock power cable
(D) 4-way data bus cable
Bus termination
Refer to CDC4 Door Controller Installation and Programming
Manual for correct bus termination instructions.
Wiegand reader connection
See Figure 1, item 12.
BZ: Open collector output to control reader beeper if fitted.
L1: Open collector output to control reader LED.
L2: Open collector output to control reader LED.
D1: Data connection to reader.
D0: Data connection to reader.
0V: Negative power supply connection to reader.
+12V: Power supply connection to the reader (450 mA
max. for both readers if powered from CDC-2DWIF).
Door lock and door contact connection
The connection of door locks and door contacts is described in
CDC4 Door Controller Installation and Programming Manual.
DIP switch settings
Select the required DGP address using DIP switch (Figure 1,
item 6). See Figure 3 for correct address settings.
LEDs
See Figure 1, items 4 and 5.
Tx: Red LED flashes when remote units (RAS and DGP)
are replying to polling.
Rx: Yellow LED flashes when panel is polling remote
units. It must always be active.
Programming
For information on the programming, see CDC4 Door
Controller Installation and Programming Manual.
Specifications
Power supply voltage
Minimum
Typical
Maximum
Current consumption
Nominal
Maximum
Wiegand reader supply current 450 mA max.
End of line resistor (standard)
P/N 1988072435 MA-466-5546-ML • REV E • ISS 23DEC20
9.5 V
0.2 V
13.8 V
15 V
73 mA
523 mA
Note:
Each active relay adds 55 mA
4.7 kΩ, 5%, 0.25 W (2.2 kΩ or 10 kΩ)
Onboard outputs
Onboard inputs
Dimensions (W x D x H)
Weight
Operating temperature
Regulatory information
Manufacturer
Carrier Fire & Security Americas Corporation, Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
Authorized EU manufacturing representative:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
Carrier Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see firesecurityproducts.com or
www.aritech.com.
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
recyclethis.info
Product
Please consult the following web link to retrieve
documentation
the electronic version of the product
documentation.
This link will guide you to the EMEA regional
contact page. On this page you can request your
login to the secured web portal where all manuals
are stored.
https://firesecurityproducts.com/en/contact
2X relay (see CDC4 Door Controller
Installation and Programming Manual
for specifications)
4X input (see CDC4 Door Controller
Installation and Programming Manual
for specifications)
128 x 78 x 21 mm
255 g
0 to +50°C
3 / 24

Publicidad

loading