WARNING
• If you are a mother who is infected with Hepatitis B, Hepatitis C or Human Immunode ciency Virus (HIV), pumping
breast milk will not reduce or remove the risk of transmitting the virus to your baby through your breast milk.
• Powered breast pumps that are designed for single users should never be rented or shared.
• This breast pump should not be operated while traveling on an airplane.
Contraindications
There are no known contraindications.
Precautions
• If discomfort is felt, suction can be broken by inserting a nger between the breast and the breast shield.
• If irritation or discomfort continues to occur, discontinue use and contact your healthcare provider.
• Before each use, visually inspect the individual components for cracks, chips, tears, discoloration or deterioration.
In the event that damage to the device is observed, please discontinue use until the parts have been replaced.
• Inspect the tubing. If you nd condensation in the air tube, wash and dry it immediately or replace the tubing.
If you see breast milk inside the tubing or tubing connector, do not attempt to wash, clean or sterilize the
tubing - contact Dr. Brown's Customer Service. Outside of the US and Canada, contact your local distributor.
Intended Use
The Dr. Brown's Natural Flow® Custom ow
lactating women to express and collect milk from their breasts. This pump is intended for a single user.
Product Description
The Dr. Brown' s Natural Flow® Custom ow
of double pumping. The device is electrically powered from an external AC powered supply and is provided non-sterile.
The Double Electric Breast Pump consists of the pump unit, breast shields, tubing, bottle vessel, duckbill valve,
and other related accessories. The materials used are silicone (SoftShape™ Silicone Shields, nipples,
membranes, duckbill valves), polypropylene (pump body and bottle vessels) and acrylonitrile butadiene
styrene (pump unit). The electric breast pump's drive unit employs a diaphragm type vacuum pump, powered
by a DC motor, supervised by a microcontroller. The microcontroller provides control over motor speed (vacuum
creation) and solenoid (vacuum release).
The pump is reusable and intended for direct user contact. The pump contains both back ow and over ow
protection. The pump is not meant to be sterilized.
Additional parameters: Maximum suction pressure with no software control is -295mmHg. The shelf life of the
pump is 2 years. This pump complies with safety standards IEC 60601-1 and IEC 60601-1-11.
Model BF100 has 2 modes:
1. Letdown Mode – Used to stimulate the release of milk from the breast.
2. Expression Mode – Used after the breast is stimulated to release milk.
PLEASE DO NOT RETURN THIS PUMP TO THE RETAILER
If you experience any issues with your Dr. Brown's Pump, please contact our dedicated
Breast Pump Customer Service team by calling 1- 833-224-7675.
1
Double Electric Breast Pump is a powered breast pump used by
TM
Double Electric Breast Pump is a personal use electric breast pump capable
TM
Outside of the US and Canada, contact your local distributor.