3.2
Technical data
Nominal load according to EN 1398
Voltage supply
Motor
•
Power
•
Operating mode
•
max. duty cycle
Protection type
Permissible inclination of the dock leveller
platform according to EN 1398
Permissible ambient temperature during
operation
Maximum permissible traversing speed
Sound pressure level L
3.2.1 Door dimensions
B H
Fig. 3: Exemplary representation, illustration may deviate from the product
OL
Overall length (NL + 330 mm)
IL (GL)
Inclination length (NL + 190 mm)
NL
Nominal length
NW
Nominal width
NL
DH (BH)
2000
590
2500
590
2750
590
3000
590
NW: 1710, 1750, 1960, 2000, 2060, 2100, 2160, 2200 and 2250 for all sizes
All dimensions in mm.
26 - EN
pA
L L
A
B
A (LL = 400)
360
380
390
400
60 kN
40 kN (for forklift trucks with very small wheels)
3 N~, 400 V, 50 Hz, 16 A
0.75 kW
S3
20 %
IP 65
12.5 % (7°)
−20 °C ... +40 °C
7 km/h
< 70 dB(A)
O L
G L
N L
HL (LL)
Hinged lip length
DH (BH)
Design height
A
Upper bridging
B
Lower bridging
B (LL = 400)
300
270
270
260
These assembly, operation and maintenance instructions must be kept for the entire period of use!
N W
A (LL = 500)
B (LL = 500)
230
340
260
300
270
300
280
300