Voltage
Frequency
Output P
nom
Max. flow rate*
Max. Suction height
Max. pressure
Max. flow height
Max. delivery temperature
Max. grain size of the dirt particles
that can be transported
Pump type
Values determined as per EN ISO 20361
Reason for exception according to regulation (EU) 2019/1781 Annex I Section 2 (12): (j)
Sound pressure level L
Sound power level L
WA,
teed
Weight (without accessories)
Subject to technical modifications!
*The max. flow rate is derived from the measurement without the backflow valve installed.
m
70
60
50
40
30
20
10
1000
2000
3000
The possible delivery rate is even larger:
- the smaller the suction and delivery heights are.
- the larger the diameter of the hoses used are.
- the shorter the hoses used are.
- the less loss of pressure is caused by the connected accessories.
BP 2 Garden Set Plus
V
Hz
W
l/h
m
MPa
(bar)
m
°C
mm
dB(A)
pA
guaran-
dB(A)
kg
10m = 0,1MPa (1bar)
4000
5000
6000
Specifications
BP 2 Garden
BP 3 Garden Set Plus
230 - 240
50
700
3000
8
0,35
(3,5)
35
35,0
1,0
Jet
57
72
8,1
I/h
– 4
EN
BP 3 Garden
BP 4 Garden Set
230 - 240
50
800
3500
8
0,4
(4,0)
40
35,0
1,0
Jet
61
76
8,3
BP 4 Garden
230 - 240
50
1000
4000
8
0,45
(4,5)
45
35,0
1,0
Jet
60
75
9,0
13