Filling the tank
CAUTION
• Install the equipment on a flat, firm
and level surface before filling the tank.
• The battery heats up during the
CAUTION
operation of the equipment, so it is inadvisable to use
liquids that may curdle in the heat.
Start-up and operation control
• Before turning on the equipment, make sure that the tank is
not empty, otherwise the pump will be damaged.
• To turn on the equipment install the switch (B) in the on
position " — ".
• Hold the handle, open the valve (C) and start spraying.
• To adjust the pressure, turn the pressure regulator (D).
• To stop the equipment, install the switch in the off position
" O ". Finally close the valve.
When the power load is low, the spray flow will gradually
decrease and the battery will need to be recharged. The
battery can be recharged at any time, it is not necessary to
fully consume its charge to recharge again, this does not
affect its lifetime.
After spraying
• After finishing the job, discharge the remaining liquid,
wash the inside wall of the chemical container with clean
water.
• Add water into the tank, turn on the equipment, point
the nozzle at a chemical container and spray for 2-3
minutes so that the inside of the pump, hose and nozzle
are clean.
8
ENGLISH
A
Star up
CAUTION
• BEFORE USING THE SPRAYER WITH
CHEMICALS, YOU MUST TEST THE TANK USING
RUNNING WATER. If you find any leaks or malfunctioning
parts, repair or replace before using any chemicals.
CAUTION
• Determine the proper amounts of
chemical concentrate and water to prepare the spray
mixture. The ratio is indicated on the label of the
concentrated chemical container.
• Remove the tank lid and make sure the particle filter (A)
is in place.
• Pour the appropriate amount of mixture into the tank, after
pouring hold the container upside down for a minimum of
30 seconds to empty completely.
CAUTION
• Do not exceed the limit marked on the
tank.
• Close the tank by screwing the lid clockwise until the tank
is perfectly sealed.
CAUTION
• Wipe up any spillage so that the liquid
does not reach the battery or the electrical system.
D
• At the bottom of the tank there is a filter net to prevent
particles from being sucked in by the pump. To avoid
clogging, clean the filter regularly. To clean it, remove the
filter from the bottom of the tank to clean it carefully.
Carefully fix it in place after cleaning.
C
N
V
Volt