J
.P. SELECTA s.a.u.
CODIGO 80418 REV 0
External control interface technical parameters
External control interface technical parameters
E-C INPUT INTERFACE DEFINITION
Notes:
1.The external control interface is a selective accessory.
2. The using method of the external interface: (A) Enabled wire and Ground
True color LCD touch screen, convenient and intuitive.
wire connect or shut, control the entry of the external control. (B) Start/
With flow calibration function, making the flow control more precise,
applicable to transferring quantitative fluid.
Stop 1 wire and Ground wire connect or shut, control the start and stop
Notes: 1.The external control interface is a selective accessory.
Large graphic LCD screen used in conjunction with the key switches,
of the pump; Start/Stop 2 wire and Ground wire control the start and stop
2. The using method of the external interface: (A) Enabled wire and Ground wire connect or
makes the man-machine interface friendly and easy to use.
through the voltage signal (less than 30V). (C) Direction wire and Ground
shut, control the entry of the external control. (B) Start/Stop 1 wire and Ground wire
With RS485 communication interface, our company can provide
wire connect or shut, control the running direction of the pump. (D) Between
communication protocols for customers. And also to customize the
connect or shut, control the start and stop of the pump; Start/Stop 2 wire and Ground wire
Speed wire and Ground wire, join up 0-5V, 0-10V, 4-20mA, 0-10kHz, etc.
software of the host computer is available.
control the start and stop through the voltage signal (less than 30V). (C) Direction wire and
controlling wire signal.
Higher cost performance.
Ground wire connect or shut, control the running direction of the pump. (D) Between Speed
wire and Ground wire, join up 0-5V, 0-10V, 4-20mA, 0-10kHz, etc. controlling wire signal.
If you need other functions, please contact the manufacturer for external
control.
If you need other functions, please contact the manufacturer for external control.
Drive external control interface (DB-15) introduction:
The 15-pin interface on the back of the machine is the controlling
interface to operate the machine through the external signals.
Firstly prepare a DB15 connector (with holes) and various colors signal
wires, then open the 15-pin interface, weld on the signal wires according
to the below sheet, and fix the wires together using the clip on the
interface, you may inject some glue to reinforce these wires; and at last
install the shell and screws.
15
Autovía A-2 Km 585.1 Abrera 08630 (Barcelona) España
e-mail: selecta@jpselecta.es - website: http://www.grupo-selecta.com
Intelligent dispensing type peristaltic pumps
Product Introduction
Use of dispensing type of crawling pump
Functions & Features
The external control interface technical parameters
1
9
2 10 3 11 4 12 5 13 6 14 7 15 8
The external control interface sketch
11/2021
E-C OUTPUT INTERFACE DEFINITION
Suspended
E-c output enable output B
Start/stop output B
Direction Output B
E-c Ground
4 ~ 20mA output negative
E-c Ground
E-c Ground
E-c output enable output A
Start/stop A
Direction Output A
0~10kHz output
4 ~ 20mA output positive
0~10V output
0~5V output
Tel 34 937 700 877 Fax 34 937 702 362
Pag.: 23