Installation Instructions
4 ELECTRICAL REQUIREMENTS (CONT)
This appliance must be supplied with the proper voltage
and frequency and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker
or fuse. See the rating plate located on the oven frame
to determine the rating of the product.
Rating Plate Location
NOTE: Rating plate is located on oven side trim, side
front frame or lower front frame.
5 MAKE ELECTRICAL CONNECTIONS
WARNING
Switch power off at the service
panel and lock the service disconnecting means to
prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
Place oven on table or platform even with the cutout
opening. Connect the flexible conduit to the electrical
junction box as shown*. Position the conduit in such a
manner that it will lie behind the unit in a natural loop
when the oven is installed. You will need to purchase
an appropriate strain relief clamp to complete the
connection of the conduit to the junction box.
* O vens come equipped with a 40" long conduit. If a longer conduit is desired, there may be one available for your model. To check availability or order
parts, call 800.561.3344.
31-2000374 Rev. 1
Use the chart below to determine the minimum
recommended dedicated circuit protection:
KW Rating
240V
≤4.8 KW
4.9 KW–7.2 KW
4.2 KW–6.2 KW
7.3 KW–9.6 KW
6.3 KW–8.3 KW
9.7 KW–12.0 KW
8.4 KW–10.4 KW
DO NOT shorten the flexible conduit. The conduit strain
relief clamp must be securely attached to the junction
box and the flexible conduit must be securely attached
to the clamp. If the flexible conduit will not fit within the
clamp, do not install the oven until a clamp of the proper
size is obtained.
The 3 power leads supplied with this appliance are
suitable for connection to heavier gauge household
wiring. The insulation of these 3 leads is rated for
temperatures much higher than the temperature rating
of the household wiring. The current-carrying capacity
of the conductor is governed by the wire gauge and the
temperature rating of the insulation around the wire.
Junction Box Location
Conduit
Place oven on a
support to assist in
connecting conduit,
must support
220lbs (99.8 kg).
Recommended
KW Rating
Circuit Size
208V
(Dedicated)
≤4.1 KW
20 Amp
30 Amp
40 Amp
50 Amp
Ground
Red
White
Black
Strain Relief Clamp (not
included) must be used
at Junction Box.
7