Descargar Imprimir esta página

Chapin 6-9215 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

Important return safety instructions:
When you return your pump for warranty or repair, you must:
1. Flush chemical residue from the pump. Run clean water through the pump for at least 15
minutes if the pump can cycle. If not, rinse thoroughly with hose inside and out.
2. Clearly label the pump with the type of chemicals that have been cycled though the pump.
3. Include complete description of operation problem, such as how pump was used,
symptoms of malfunction, etc.
Pumps can contain residues of toxic chemicals. Carefully follow appropriate steps to protect
all of those who handle return shipments, and our lab technicians that evaluate the isuues
with your return.
Please call the Chapin International, Inc. before returning any product.
1-800-950-4458
CAUTION:
DO NOT OPERATE PUMP IN AMBIENT FREEZING TEMPURATURES.
STORAGE
Protect the pump from freezing during storage. Fill pump system with RV antifreeze.
RV antifreeze is the preferable choice. It is biodegradable and generally safer than
most antifreeze solutions. Be sure to spray some through the entire system to ensure
that all components are protected from freezing.
REMOVING FROM STORAGE
Drain unit of all antifreeze. Be sure to safely collect the antifreeze. Flush enitire system
with clean, fresh water until pump is completely clear of antifreeze. Dispose of Anti-
freeze properly according to local code.
4E
Instruction Manual - English

Publicidad

loading