Descargar Imprimir esta página

Kichler 15PR100SS Instrucciones De Instalación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

PLEASE READ ALL WARNING AND CAUTION STATEMENTS
AND COMPLETE ALL INSTALLATION INSTRUCTIONS
ON PAGE 1 BEFORE FOLLOWING
INSTALLATION INSTRUCTIONS ON PAGE 2
INSTALLATION INSTRUCTIONS (CONTINUED)
6.
Split Kichler SPT Direct Burial Wire 12/2 or 10/2 cable approximately 3" (76 mm), and
strip 1/2" (12 mm) insulation off each wire. 12/2 and 10/2 cable is the heavy black cable
with which all Kichler® 12-volt low voltage lighting fixtures will be connected.
(Reference "Direct Burial 2 Conductor SPT Cable" chart on Page 1 for description and
part numbers).
7.
On the bottom of the terminal block [E] push one bare wire into the hole marked "COM"
and tighten the corresponding screw on terminal block face until wire is secure. Torque
terminal blocks screws to 32 - 35 lb-in (3.6 - 4.0 N-m). See chart for maximum wire sizes
based on gauge:
Wire Gage Size
#12
#10
HOUSING
CONNECTOR
7/8" (22 mm)
DIAMETER CAPS
SHORT POWER
CORD
TIMER
RECEPTACLE
8.
For more information on voltage drop, consult the Kichler Landscape Lighting Catalog,
or contact your local Kichler distributor.
• Push remaining bare wire into the hole marked 15V on bottom of terminal block and
tighten the corresponding screw on terminal block face until wire is secure. Again,
refer to the torque specifications in Step 7. Ensure that the insulation is not under the
terminal plate. Check all connections after installation. See "Risk of Fire" warnings in
"CAUTIONS" section of this instruction guide.
9.
A receptacle and a short power cord are located above the terminal blocks.
• If using plug-in timer (15556WH/15557BK):
o Make sure power is off and the power supply is NOT plugged into an electrical outlet.
o Plug timer into receptacle.
o Plug short power cord into timer.
o Set timer following instructions provided with timer.
• If not using plug-in timer, plug the short power cord into receptacle. (The power
supply is shipped in this configuration.)
10. Optional Photo control Installations:
• Make sure power is off and the power supply is NOT plugged into an electrical outlet.
NOTE: No splice is required, the power supply is equipped with a jumper connector.
• Open front cover of the transformer power unit case by lifting the cover up. Locate
and disconnect the white jumper connector inside the housing. Save the jumper
connector with these instructions for possible future use.
• Remove one (1) of the 7/8" (22 mm) diameter caps on the side of the power supply and
push the photo control white connector through the knockout hole. Inside the housing,
slide the spacer and star nut over the white connector and thread it on to the photo
control and tighten.
• Plug the photo control white connector into the housing connector. Ensure that the
side latch locks the connectors together.
• Locate the power supply and position the photo control so that no light will shine on
the cell. It will cause the photo control to cycle on and off. *In the unlikely event that the
photo control should fail, the lighting fixtures will remain on, even in the daytime. If this
should happen, follow these instructions, and remove the defective photo control and
place the jumper connector in its place.
11. Plug power supply cord into standard 115/120 volt receptacle.
NOTE: The power supply cord must be plugged into a weather tight receptacle
equipped with a Ground Fault Interrupter (GFCI).
REV 24-JUN-2022
Max. number of conductors
8
4
JUMPER CONNECTOR
CIRCUIT BREAKER
TERMINAL BLOCKS [E]
TIGHTENING SCREW
CABLE ENTRY FOR COMMON
CABLE ENTRY FOR 15V
For warranty information please visit: kichler.com/warranty
INSTALLATION INSTRUCTIONS (CONTINUED)
If the unit cycles on and off without regard to the timer setting or other controls,
it should be checked by a qualified service person.
• Circuit breaker on the Secondary / 15V side will trip if there is a short or if total
wattage installed exceeds rated wattage per circuit. To reset breaker, flip switch
to "OFF" then back to "ON" position.
• Thermal protector on the Primary / 120V side will shut off unit if overheated.
PAGE 2
866-558-5706
We're here to help
Hrs: M-F 9am to 5pm EST
IS-15PR100SS-US

Publicidad

loading

Este manual también es adecuado para:

15pr200ss15pr300ss