Attention: If you find the drain blocked, do not apply Drainspexx!
7.3. Select Adapter
• In case of a cylindrical drain line easy to access.
• Select appropriate adapter according to diameter of drain line
Adapter 1
X
Adapter 2
Adapter 3
• Screw the nozzle and adapter together, approximately 1,5 turns.
• Push adapter incl. nozzle into drain line until line is closed firmly
Attention: If the lips of the adapter are damaged or the adapter does not seal correctly, do not use further!
Check for a tight fitting to the drain line wall, note that 2 libs (upper or lower) must seal the drain line (See
110008050)
7.4. Start/Stop fogging
•
Open air valve, see layout drawing pos. 5 (turn handle 90 °).
•
Check noise of nozzle. (If no noise appears, check air supply.
•
Open biocide valve.
•
Apply for 3 min.
•
Finally close valve, remove adapter.
•
Use trigger spray bottle filled with biocides to disinfect the adapter.
•
Spray biocide onto the surfaces of the drain and pipe entrance where the adapter was placed during Drain-
spexx application.
•
After applying Drainspexx to a drain, make sure that the siphon is reinstalled into the drain, in such way
that it fulfills its intended purpose.
•
Disconnect air supply.
•
Hang up the air tube loops and the other tubes at the trolley.
•
Move to the next drain to conduct the treatment.
Attention: The content of the air tube will vent into the room causing some noise!