INSTALLATION INSTRUCTIONS
Multiple Bodyspray Installations
Route the water supply lines.
If installing more than one bodyspray off the same supply line, construct a pressure balancing loop. Locate a
tee along the loop at each bodyspray installation location.
Do not strap the pipes at this time.
Single Bodyspray Installations
Route the water supply line.
Install an elbow to the end of the supply pipe at the bodyspray installation location.
All Installations
Temporarily install a nipple to each tee/elbow. Do not use any sealant.
Verify that the nipple(s) will extend 1/2" beyond the finished wall when fully tightened.
Install appropriate backing and strap the pipes.
Finish the wall.
Verify that the hole in the finished wall is 1-1/8" in diameter.
Install a 1/2" NPT pipe nipple so that it extends 1/2" beyond the finished wall when fully tightened.
Run water through the system to flush out dirt and debris.
Apply sealant tape around the exposed threads of the pipe nipple.
1506285-2-A
3 of 11
1. INSTALL THE SUPPLY PIPING
Multiple Bodyspray Installation
Water Supply
Pressure Balancing Loop
2. INSTALL THE PIPE NIPPLE
Finished Wall
TurnSpray
Single Bodyspray Installation
Nipple
1-1/8"
(2.9 cm)
1/2"
(1.3 cm)
1/2" Pipe Nipple
Apply sealant tape.
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
Bodyspray
™