Descargar Imprimir esta página

Filter Systems - Maxvac Dustblocker PRO Instrucciones De Uso Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
If you link several Dustblocker Pro in a row, the total power should not
be higher than the maximum allowed power of the socket.
FILTERS AND FILTER
OPERATION
The Dustblocker Pro separates the dust in
three phases:
During the first phase, the g3 flter cloth is used. The g3 filter cloth collects the
largest dust particles.
During the second phase, the G4 pre filter is used. The filter collects the largerdust
particles and protects the Pre and H13/14 hepafilter.
During the second phase, the F9/H13/14 hepafilter is used. This filter will collect
the dust that is dangerous for people's health and that is not visible to the naked
eye.
See the replacement table containing the recommended periods for changing all
filters.
For replacing the Pre Filter as well as the Main Filter you must take the airflow into
account. The air is sucked in at the side of the filters and blown out at the opposite
side.
At the front of your Dustblocker Pro you will see a G3 filter. In case of daily use, we
recommend changing it every 2 months (depending on the contamination)
Turn off the machine and unplug the power cord. Remove the filter cover by
loosening both springs and sliding the cover forward.
8
DB PR O
MAX-VAC.COM

Publicidad

Solución de problemas

loading