_fr-145.book Seite 28 Montag, 14. August 2006 4:03 16
Technical data
Poor cooling capacity, higher interior temperature
Fault
Compressor runs for a
long time/continuously
Compressor runs
intermittently
Error messages
In case of an error, the following messages are displayed:
Display
Explanation
EE
Data or memory error:
Pull off the connection cable and re-connect the cooler.
P1
The temperature sensor does not work:
Have the temperature sensor replaced.
11
Technical data
Overall capacity
Connection voltage
Average power consumption
Cooling temperature range
Dimensions (WxHxD) in mm
Weight
Test/certificates
Versions, technical modifications and delivery options reserved.
This device is CFC-free.
The coolant circuit contains R134a.
28
Possible cause
Ambient temperature too high or set
cooling temperature too low
Insufficient ventilation and/or cooling
Battery capacity exhausted
136 litres (divided into two compartments
with 97 l and 34.5 l)
12/24 Volt DC or 110–240 Volt AC
65 Watts
0 °C to +12 °C
1206x570x520
35 kg
FR-145
Remedy
–
Move the cooler to
another position
Charge the battery