When the test is complete, the test results must be confirmed by the user. See the
section titled "Test Results" below.
The Full Test is performed in accordance with the section "Performing the Full Test"
and automatically performs the following tests:
- Cylinder pressure above pre-set level (configuration dependent)
- Battery has at least two hours of operation
- Electronic systems are working
- Leak tightness
- Air flow capacity
When the test is complete, the test results must be confirmed by the user. See the
section titled "Test Results," below.
TEST RESULTS
When the test is finalized, the display reads "TEST OK", or shows a failure indication.
Should there be more than one failure, the indications are given in sequence.
Pressing the backlight button (section 7, Fig. 7-A) toggles to Run mode or to the next
failure indication. If the backlight is not lit, the first press on the backlight button will
light the backlight and a second press will toggle to Run mode or to the next failure.
TEST OK
PRESS LEFT
FAILURE INDICATION
LOW CYL !!!
LOW BATT
LEAKAGE
CAPACITY
ADSU/PASS
1)
Replace battery immediately after the current operation or if possible before the operation is continued.
2)
Only conducted if Full Test is performed
ATTENTION! ALWAYS FOLLOW YOUR ORGANIZATION'S POLICY TO DETERMINE WHETHER AN OPERATION MAY BE
PERFORMED AFTER THE OCCURRENCE OF FAILURE INDICATION(S).
PERFORMING THE "SHORT TEST"
Open the cylinder valve fully. The display reads according to the figure below.
1.
INTERSPIRO
12
FAILURE
LOW CYL !!!
EXPLANATION
CYLINDER PRESSURE BELOW PRE-SET LEVEL (CONFIGURATION
DEPENDENT)
BATTERY HAS LESS THAN 2 HOURS OF OPERATION
THE UNIT FAILED THE LEAK TIGHTNESS TEST
THE UNIT FAILED THE AIR FLOW CAPACITY TEST
THE UNIT FAILED THE MOVEMENT SENSOR TEST
1)
2)
2)
2)