CHOICE OF LOCATION/INSTALLATION INSTRUCTIONS
Do not install the unit in the following locations as this may
cause malfunction.
- Do not install the outdoor unit near a source of heat,
steam or flammable gas.
- A place containing high-frequency appliances
(e.g. welding machine, medical equipment).
- A place near a coastal area.
- A place with oil or smoke in the air.
- A place with sulphuric gas.
- Other places with special conditions.
INDOOR WALL UNIT
Select a location that is strong enough to support the weight
of the unit and that does not accentuate noise or vibrations
generated by the unit's operation. The inlet and outlet ports
must not be blocked: air must be able to circulate throughout
the room.
Install the air conditioner near a power source.
Install the air conditioner where it will be easy to make the
connection between the wall unit and the outdoor unit.
Install the air conditioner where it will be easy to drain off
condensed water.
The system must be installed more than 2 m above the ground
Check the necessary gaps as shown opposite to ensure
accessibility.
Install the air conditioner where the filter will be easily accessible.

OUTDOOR UNIT

Do not install the unit in a windy or dusty place.
Do not install where there is a lot of traffic.
Select a location where the airflow and noise will not disturb neighbours.
Avoid installing the outdoor unit where it will be exposed to direct sunlight
(If this is not possible, use a cover, if necessary, which will not hinder the
air circulation).
Leave enough space for good air circulation, as shown on the right.
Install the outdoor unit in a safe and solid location.
If the outdoor unit is subject to vibration, secure it with silent blocks (rubber
buffers) to be positioned under the fastenings.
ATTENTION: Maximum length of the refrigerant lines 12 metres.

INSTALLATION DIAGRAM

ELECTRICAL INSTALLATION:

ensure that a separate power supply circuit is used, specific to the air conditioner.
38
Ground
Installation conditioned by
the maximum length of the
refrigerant lines 12 metres
12 metres max.
Mounting plate
Condensate pipe
Sleeve
Insulation
Electrical cable
Condensate pipe
Minimum space required (in mm)
Outdoor
unit
Indoor
Installing the outdoor
unit
unit at more than 3 metres
height of the indoor unit
requires the use of oil traps
Oil trap
8