DESCRIPTION
BY-PASS KNOB
"Push for by-pass"
HARDNESS
MIXING-KNOB
"+ and - symbols"
WATER INLET
INSTALLATION OF
SAMPLING-TAPS ON THE
"KIT FACILE"
MAN 145
KIT FACILE - ENGLISH
PUT THE SYSTEM IN BY PASS WITH "KIT FACILE": push the by-
pass knob up to the end of stroke, and turn the hardness mixing-
knob counter clockwise towards the "-" symbol up to the limit
(in order to close all the passages of water).
PUT THE SYSTEM IN WORKING POSITION (NO BY-PASS): pull
the by-pass knob outwards. If the water softener is installed, and the
mixing of hardness is done by the KIT FACILE, adjust the mixing by
turning the hardness mixing-knob toward the "-" symbol, in order to
increase the hardness value.
WATER HARDNESS MIXING BY THE MEANS OF "KIT FACILE"
(WHEN A WATER SOFTENER IS INSTALLED).
TO PUT THE "KIT FACILE" IN WORKING POSITION (NO BY-
PASS), PULL THE BY-PASS KNOB OUTWARDS BY PRESSING
THE HARDNESS MIXING-KNOB.
WATER HARDNESS MIXING BY THE MEANS OF "KIT FACILE":
Turn the knob towards the "+" symbol to increase water hardness.
Turn the knob towards the "-" symbol to decrease water hardness.
TO PUT THE SYSTEM IN BY PASS WITH THE KIT FACILE, push
the by-pass knob up to the end of stroke, and turn the hardness
mixing-knob counter clockwise towards the "-" symbol up to the limit,
in order to close all the passages of water.
TO PUT THE SYSTEM IN WORKING POSITION (NO BY-PASS),
pull the by-pass knob outwards (see the instruction of the previous
point "BY-PASS KNOB").
THE INLET OF WATER CAN BE SET BOTH TO THE LEFT AND
RIGHT SIDE (OR BOTH FROM UP AND DOWN POSITION, IF THE
"KIT FACILE" IS INSTALLED VERTICALLY).
ATTENTION: The water inlet of BravoCAB water softener is to the
right side.
N.B. "KIT FACILE" allows the integrated installation of n.2 water
sampling-taps.
Frontally to the "KIT FACILE", two housings for the installation of
water sampling-taps are available (water sampling taps are not
supplied with the KIT FACILE).
The water sampling taps allow to check water values before and after
the water treatment. In order to install the water sampling-taps on the
"KIT FACILE", remove the closure stopper.
FUNCTION