Installing the magnetic sensor for vertical shaft anchor
windlasses
(see Fig. 1A – 1B)
Drill a 4 mm (~3/16") hole in the cover through which to
thread the sensor cable.
Fasten Part A of the support with the two screws
provided, after having positioned the O-ring in the
lower part of the support.
Fit Part B with the magnetic sensor on support A and
adjust its height until it is aligned with the magnet
fastened on the gipsy.
Bring the sensor to a distance of about 3 mm (~1/8")
from the magnet and secure it in place by tightening
screw G1. Then tighten screw G2.
Installing the magnetic sensor for
horizontal shaft anchor windlasses
(see Fig. 2A – 2B – 2C)
Drill a 4 mm (~3/16") hole in the cover through which to thread
the sensor cable.
Fasten Part A of the support with the two screws provided, after
having positioned the O-ring in the lower part of the support.
Cut Part C to measure using a hacksaw. The sensor must be
positioned at a distance of about 3 mm (~1/8") from the magnet.
Fit Part C with the magnetic sensor on support A and fix it in
place using an adhesive for plastic (two-component epoxy glue)
or silicone.
Using the same glue, attach the sensor to Part C.
EV-011
G1
G2
17
English
B
A
OR
C
A
OR
Rev. 07 – 2010