Descargar Imprimir esta página

Nilfisk CTS22 Manual De Instrucciones página 38

Ocultar thumbs Ver también para CTS22:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CTS22 - CTS40 - CTT40
Get four cartridges with the same characteristics. These
will be supplied with the gasket which must be positioned
in the relevant housing on the lower side of the cartridge
fastening flange.
Gasket replacement is of the utmost importance since
it must ensure a perfectly tight seal between the filter
chamber and cartridge, thus preventing dust from
leaking out.
Fit the tank back in place by repeating the above
operations in reverse order.
Primary filter replacement, for machines equipped
with electric filter shaker cleaning system
Remove the hose from the upper inlet.
Release the closing band and remove the cover.
Sling the cover and lift it carefully, because the star-shaped
filter and the shaking cage are connected to the cover.
Do not rest the cover-star-shaped filter assembly
vertically on the ground, but use suitable supports or
rest it sideways, as the weight of the cover can damage
the filter and the shaking cage.
Lift the filter (6), unscrew the clamp (7) and remove the
ring (8).
Cut the clamps (10) and detach the cage from the filter.
Fit the filter catch and retention ring of the old filter on to
the new one.
Insert the cage (9) and fix it to the filter by means of the
clamps (10) on the bottom of the filter itself.
After removing the plastic cover, check that:
-
The lever (11) fastened to the drive shaft (12) of the
cage (10) must be halfway along its travel in the
neutral central position.
-
The connecting rod (13) fastened to the reduction unit
(14) must point downwards. Only in this way, when
operating the reduction unit (14), the cage (10) will
cover an equal travel to the right and left when, without
tightening the filter (8). The filter could be torn and the
GB
motor of the reduction unit burnt out if this is not done.
Fit the filter into the filtering chamber, then mount the
cover and lock it in place with the two fastening latches.
Before closing the hooks to lock the cover, shake the filtering
unit by hand in order to remove any small positioning
defects.
Fit the vacuum hose on the upper inlet.
Primary filter replacement for machines that handle
dusts that are hazardous to health.
To replace the primary filter safely, follow the instructions
according to the type of filter/cleaning system installed on the
machine, and proceed as follows:
Insert the plug (1) in the vacuum inlet.
Insert the belt (2) around the filter chamber.
C313
CAUTION!
Figure 17
CAUTION!
CAUTION!
Figure 18
Place the bag with the elastic band on the filter chamber
(3). Tighten the safety belt (4) on the bag, above the band.
Tuck in the bag along its length. (5)
Remove the star filter (6) by grasping the ring with the
gasket and lift it until it is completely out of the filter
chamber (7).
Turn the bag on itself to obtain a section of coiled bags to
be tightened with two clamps (8). Place the two clamps at
a distance of 50 mm between them, then cut in-between
(9) as shown in the figure.
Dispose of the filter (10) according to the laws in force.
Loosen the belt (11) and carefully move the bag elastic
band (12) towards the filter chamber upper edge.
Insert the second bag (13) over the first bag (14) and
tighten the safety belt (15) on the new bag.
Through the new bag (13) carefully remove the crop of the
first bag (14) from the edge of the filter chamber.
Bring the crop (14) towards the end of the second bag
(13).
Turn the bag (13) on itself to obtain a section of coiled
bags and close of the crop (14) at the bottom of the bag
(13) by tightening the clamp (16)
Loosen and remove the belt and gently remove the bag
from the edge of the filter chamber.
Upstream absolute filter replacement
Loosen the clamp with a screwdriver and remove the
vacuum hose (1).
Unscrew the knob (2).
Unlock the safety bolt (5).
Use the lever (4) to release the cap (3) then pull it up and
out of the vacuum cleaner.
Unscrew ring nut (6)
Pull out fastening disc (7) and absolute filter (8)
Place absolute filter (8) in a plastic bag, close the bag
hermetically and dispose of the filter in accordance with
the laws in force.
Insert a new filter (8) with the same filtering characteristics
as the removed one
Lock the absolute filter with disc (7) and tighten the ring
nut (6)
Insert the cap (3) again.
Fix the cap in place with the lever (4) and lock the safety
bolt (5) again.
Screw the knob (2).
Fit the vacuum hose (1) back in place and tighten the
clamp
Lock it retightening the four nuts (1).
Downstream absolute filter replacement
Unscrew the knob and remove the cover.
Remove the absolute filter and place it in a plastic bag,
close the bag hermetically and dispose of the filter in
accordance to the laws in force.
Insert a new absolute filter with the same filtering
characteristics as the removed one.
Reinstall the cover by fastening it with the knob.
16
Figure 19

Publicidad

loading

Este manual también es adecuado para:

Cts40Ctt40Cts22 serieCts40 serieCtt40 serieCts22 hc lp ... Mostrar todo