12 | English
Cordless fan
Speed
min
Recommended ambient
temperature during
charging
Permitted ambient tem-
perature during opera-
A)
tion
Permitted ambient tem-
perature during storage
(fan)
Permitted ambient tem-
perature during storage
(rechargeable battery)
Humidity operating
range
Weight according to
EPTA-Proced-
B)
ure 01:2014
Dimensions
mm
(length x width x height)
Recommended re-
chargeable batteries
Recommended battery
C)
chargers
A) Limited performance at temperatures < 10 °C
B) Depends on battery in use
C) The following chargers are not compatible with the PBA re-
chargeable battery: AL 1814 CV, AL 1820 CV, AL 1860 CV
Noise information
Noise emission values determined according
to EN 60704-2-7.
Typically, the A-weighted sound pressure level of the fan is
less than 70 dB(A). The noise level when working can ex-
ceed the volume stated. Wear hearing protection!
Rechargeable battery
Battery charging
Use only the chargers listed in the technical data. Only
u
these chargers are matched to the lithium-ion battery of
your fan.
Note: Lithium-ion rechargeable batteries are supplied par-
tially charged according to international transport regula-
tions. To ensure full rechargeable battery capacity, fully
charge the rechargeable battery before using your tool for
the first time.
Remove the battery from the fan after the fan has
u
been automatically switched off. This can damage the
rechargeable battery.
1 609 92A 87R | (16.08.2022)
Inserting the Battery
UniversalFan
18V-1000
Push the charged battery into the battery holder until it
−1
clicks into place.
1500
°C
0 to +35
Removing the Battery
To remove the rechargeable battery, press the battery re-
lease button and pull the battery out. Do not use force to do
°C
0 to +50
this.
Battery charge indicator
–20 to +70
The battery charge indicator indicates the remaining battery
capacity or an overload for a few seconds when the operat-
ing button is pressed.
–20 to +50
LED
3 × continuous green light
2 × continuous green light
Non-condensing
1 × continuous green light
2.7 kg (1.5 Ah) –
1 × slowly flashing green
3.0 kg (6.0 Ah)
light
The three LEDs in the battery charge indicator flash quickly
254 x 310 x 414
when the temperature of the rechargeable battery is outside
the operating temperature range and/or the overload protec-
tion has been triggered.
PBA 18V...W-.
Recommendations for Optimal Handling of the
AL 18...
Battery
Protect the battery against moisture and water.
Only store the battery within a temperature range of −20 to
50 °C. Do not leave the battery in your car in the summer, for
example.
Occasionally clean the ventilation slots on the battery using a
soft brush that is clean and dry.
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
Follow the instructions on correct disposal.
Operating time
Rechargeable battery
PBA 18V 1,5 Ah
PBA 18V 2,5 Ah
PBA 18V 4,0 Ah
PBA 18V 6,0 Ah
Operation
u
Capacity
76–100 %
41–75 %
16–40 %
0–15 %
Operating time
in hours [h]
1 h 45 min–9.5 h
3 h–15 h
5 h–25 h
7.5 h–38 h
Remove the battery from the fan before carrying out
work on the fan (e.g. assembly, cleaning, etc.). The
battery should also be removed for transport and stor-
age. There is risk of injury from unintentionally pressing
the on/off switch.
Bosch Power Tools