How to program the
pre-infusion time
It is possible to regulate the
pre-infusion time as follows:
While you keep on pressing the
button P1, turn on the machine;
the led of button P1 will lighten,
turn off the machine and turn it
on again, in this way you have set
the pre-infusion time at 4 s.
If You prefer a shorter time (2
s), perform the same operation
but press the button P2 instead
of P1, the led of button P2 will
then lighten up.
In order to cancel the pre-in-
fusion time completely, follow
the procedure described here
above but press button P3 when
you turn on the machine; the
corresponding led will lighten
up, then switch off and on again
the machine.
Boiler pressure
regulation
Steam pressure in the boiler is
checked by an adjustable pres-
sostat. For pressure regulation:
• Take away upper panel (5),
take apart boiler protection (15).
• On the left back turn clockwi-
se the central screw of presso-
stat to reduce pressure or anti-
clockwise to increase pressure.
•Assemble the upper protection
(15), back panel with screw
again.