Descargar Imprimir esta página

Electrical Connection - Baxi Quantum MINI Instrucciones De Instalación Y Funcionamiento

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Turning the motor head
If the installation position of the module is changed, the
motor housing must be turned as follows:
• If necessary, remove the thermal insulation shell.
• Loosen the interior hexagonal head screws.
• Turn the motor housing, including the control module.
NOTICE: In general, turn the motor head before the sys-
tem is filled. When turning the motor head in a system that
has already been filled, do not pull the motor head out of the
pump housing. Turn the motor head with a small amount of
pressure on the motor unit so that no water can come out
of the pump.
CAUTION: Do not damage the housing seal.
Replace damaged gaskets.
• Turn the motor head in such a way that the plug corre-
sponds to the permitted installation position (Fig. 3).
CAUTION: If the position is wrong, water can penetrate
and destroy the pump.
• Turn in the interior hexagonal head screws.
• If applicable, re-mount the thermal insulation shell.
4.2

Electrical connection

DANGER: Work on the electrical connection must be
performed only by a qualified electrician and in
accordance with national and local regulations.
Before making the connection, ensure that the
connecting cable is not live.
• The mains voltage and current type must correspond to the
rating plate specifications.
• Connect the plug (Fig. 4a to 4e).
38

Publicidad

loading