Descargar Imprimir esta página

Starting The Generator; Stopping The Engine - Mi-T-M Corporation GEN-2000-iMM1 Manual Del Operador

Publicidad

Idiomas disponibles

Idiomas disponibles

STARTING THE GENERATOR:

CAUTION:
CHECK
OPERATION AS OUTLINED ON PAGE 21.
1. Make sure all appliances are disconnected from the generator
2. Open the vacuum relief valve on top of the fuel cap by rotating
clockwise to the on "I" position.
3. Turn the generator switch to the choke position.
4. Slowly pull the starter handle until resistance is felt, then quickly
pull the starter handle the rest of the way. If the engine does not
start, repeat step 6 until the engine does start.
5. After the engine has started, turn the generator switch to the on
"I" position.
CAUTION:
DO
NOT
DEFECTIVE LINES AND/OR PLUGS.
BE SURE APPLIANCES ARE NOT CONNECTED TO
GENERATOR
WHEN
GENERATOR WITH AN APPLIANCE CONNECTED COULD
RESULT IN DAMAGE TO THE GENERATOR AND/OR
APPLIANCE AND PERSONAL INJURY.

STOPPING THE ENGINE

1. Disconnect the generator / unplug all electrical devices.
2. Turn the generator switch to the off "0" position.
3. Close the vacuum relief valve on top of the fuel cap by rotating
counterclockwise to the off "0" position.
NOTE: To stop the engine in an emergency, turn the generator
switch to the off "0" position.
Operator's Manual
THE
OIL
LEVEL
BEFORE
CONNECT
APPLIANCES
STARTING
UP.STARTING
OPERATION
EACH
WITH
THE
19

Publicidad

loading

Este manual también es adecuado para:

Gen-2500-imm1