Descargar Imprimir esta página

Bellman Visit BE1480 Manual Del Usuario página 69

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
The following signal patterns are available for the Visit Smoke Alarm:
Type
LED pattern
Fire alarm
Red blinks
constantly
Fire alarm
Red blinks every
low battery
five seconds
Fire alarm
Red blinks every
flat battery
five seconds
Fire alarm system with Visit Guard Receiver
The Visit Smoke Alarm can be connected to a special fire alarm system in which a
BE1465 Visit Guard Receiver controls all the smoke alarms that are registered on the
system. The Guard Receiver Switch (8) is used for this function.
If no BE1465 Visit Guard Receiver is used in your system, the Guard Receiver Switch (8)
is in the OFF position.
See the Guard Receiver User Manual for further information.
Testing
It is easy to test the Visit Smoke Alarm. If the Smoke Alarm does not work as
described below, you can check further under Troubleshooting/Troubleshooting
guide.
How to test
Test the Smoke Alarm at least once per month and preferably each week, e.g. during
cleaning. Always test it immediately after any holidays or other extended periods of
absence.
A receiver in the Visit System which is set to the same Radio Key as the Smoke Alarm
is required to test the Smoke Alarm with the Test Button (1) or by blowing in smoke.
Proceed as follows:
Hold down the Test Button (1) or blow smoke into the Smoke Alarm. The Visit
Smoke Alarm will transmit a radio signal after about five to ten seconds.
The Visit receivers will then indicate the Smoke Alarm.
Sound
Vibration
Fire alarm
Long
constant
No
No
Fire alarm
One short
one short
69
Flash
Yes
No
DE
Yes
DK
ES
FI
FR
GB
IT
NL
NO
PL
SE
App